Connecting an External Switch to Ground
Many switches, buttons and control units in a vehicle don't switch positive, they switch ground: as soon as you operate them, they connect their wire to negative. You can connect switches like these to the external switch input of your NODE® as well. All you need is a wire jumper or a 10 kΩ resistor and one setting in the app.
Which NODEs
- NODE® Switch
- NODE® Switch Multi: Each of the five channels has its own switch input.
- NODE® Ambient and NODE® Ambient MultiWhite
- NODE® TwoWay: It has a three-pin switch input and its own section further down.
Switching positive or switching ground
Switching positive (default)
The switch connects the two terminals of the switch input with each other. In the app, the Trigger Reference is set to Vbatt – this is the factory setting.
Switching ground
The switch connects the switch input to ground. So that the input sees positive while the switch is open, a wire jumper or a resistor goes between the two terminals. In the app, you change the Trigger Reference to GND.
Connecting with a wire jumper
Connect the two terminals of the switch input with a short wire jumper. The wire to the switch goes into one of the two terminals as well – it doesn't matter which one. Connect the other side of the switch to ground.

Connecting with a 10 kΩ resistor
Instead of the wire jumper, you can fit a resistor of 10 kΩ and at least 0.25 W between the two terminals. Connect the switch the same way as with the wire jumper.
The resistor can also sit at the switch. In that case, run one wire from each terminal to the switch and fit the resistor there between the two wires. The switch goes on one of the two wires.

Both options work in 12 V and 24 V systems.
Important: The switch must switch to the same ground that the negative of your NODE® is connected to – that is, the negative of the leisure battery or the vehicle ground connected to it. Otherwise the NODE® will not detect the switch.
Important: The wire jumper and the resistor belong on the switch input only, never on the connections for loads or the power supply.
Note: Control units whose output switches to ground are connected the same way.
Setting it up in the app
Open the NODE®
Open the side menu, tap Configuration and scroll down to the Your NODE settings section.
Tap the arrow next to the channel you want. On the NODE® Switch Multi, each channel has its own row.

Set up the external switch
In the Connection section, turn on the External Switch card 1 and choose the type 2: Toggle Switch, Button, D+ On or D+ Off – depending on what you are connecting.
Below that, under Trigger Reference, tap GND 3 – this makes the NODE® evaluate the switch against ground.

Save
Scroll to the end and tap Save – only then is the setting stored on the NODE®.

After that, with a toggle switch: switch closed means on, switch open means off. A button toggles with every press.
The app only shows the Trigger Reference from these versions on. If it is missing for you, first bring your system up to date – the article How do I update my Brain? explains how.
NODE® TwoWay
The NODE® TwoWay has a three-pin switch input: the middle terminal carries positive, the two outer terminals are the inputs for the two running directions.
Fit one 10 kΩ resistor (at least 0.25 W) from the middle terminal to each input that you switch to ground. Connect the switch to the outer terminal.

Important: Don't put wire jumpers on both inputs. Both inputs share the middle terminal – with two jumpers, each switch would trigger both running directions. If you only use one input, a wire jumper there is enough.
In the app, the NODE® TwoWay has the sections Running Direction L and Running Direction R, each with its own External Switch card. Change the Trigger Reference to GND for each running direction that you switch to ground.